Recent changes
35934 changed pages · Atom feed · Recent comments · Recently added · Recent ratings
Thursday November 05 2026
- lt (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Returns TRUE if a parameter is less than another parameter. Usage input|lt( value1 [, value2 ] ) Parameters Name Type Description Required value1 any A variable/value that should be compared. Yes. value2 any Anot… - ne (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Julia Shymova on 06/29/2007
Summary Returns TRUE if one or more of the parameters do not match. Usage input|ne( value1 [, value2 [, ...] ] ) Parameters Name Type Description Required value1 any A variable/value that should be compared.. Yes. value2… - gt (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Returns TRUE if a parameter is greater than another parameter. Usage input|gt( value1 [, value2 ] ) Parameters Name Type Description Required value1 any A variable/value that should be compared. Yes. value2 any A… - le (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Returns TRUE if a parameter is less than or equal to another parameter. Usage input|le( value1 [, value2 ] ) Parameters Name Type Description Required value1 any A variable/value that should be compared. Yes. val… - ge (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Returns TRUE if a parameter is greater than or equal to another parameter. Usage input|ge( value1 [, value2 ] ) Parameters Name Type Description Required value1 any A variable/value that should be compared. Yes.… - first_set (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 05/04/2005
Summary Returns the first parameter that is set (or FALSE). Usage first_set( value1 [, value2 [, ... ] ] ) Parameters Name Type Description Required value1 any A variable/value that should be evaluated. Yes. value2 any A… - false (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 05/04/2005
Summary Creates and returns a boolean FALSE. Usage false() Returns FALSE. Description This operator creates and returns a boolean FALSE. It can be used to define a boolean variable and in logical comparisons. Examples Ex… - eq (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 05/31/2010
Summary Returns TRUE if the input equals the first parameter or if all parameters are equal. Usage input|eq( value1 [, value2 ] ) Parameters Name Type Description Required value1 any A variable/value that should be compa… - cond (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Returns the value of the first clause who's condition is TRUE. Usage cond( cond1, value1 [, cond2, value2 [, ... ] ] ) Parameters Name Type Description Required cond1 boolean Match condition 1. Yes. value1 any Re… - and (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 08/13/2010
Summary Evaluates all parameters to check if any are evaluated as FALSE Usage and( value1 [, value2 [, ... ] ] ) Parameters Name Type Description Required value1 any A variable/value to be evaluated. Yes. value2 any Anot… - choose (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Returns one of the parameters (pinpointed by the input parameter). Usage input|choose( value1 [, value2 [, ... ] ] ) Parameters Name Type Description Required value1 any A variable/value of any kind. Yes. value2… - image (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 05/04/2005
Summary Creates and returns an image object. Usage image( value [,...] ) Parameters Name Type Description Required value mixed Please refer to the description below. Yes. Returns An ezimage object. Description This opera… - l10n (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 05/05/2006
Summary Formats misc. numbers (times, dates, currencies, numbers, etc.). Usage input|l10n( type [, locale [, symbol ] ] ) Parameters Name Type Description Required type string The format that should be used. Yes. locale… - si (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 05/04/2005
Summary Handles unit display of values (output formatting). Usage input|si( unit [, prefix ] [, decimals ] [, symbol ] [, separator ] ) Parameters Name Type Description Required unit string The unit that the input value… - datetime (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Geir Arne Waaler on 10/13/2011
Summary Formats dates/times according to settings in "datetime.ini". Usage {input|datetime( preset_format [, format ] )} Parameters Name Type Description Required preset_format string Preset datetime format set in "datet… - module_params (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 07/05/2005
Summary Extracts parameters from the module that was run. Usage module_params() Returns An array containing module information. Description This operator extracts some generic information from the module that was run. It… - ezsys (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 10/07/2011
Summary Returns misc values such as wwwdir, sitedir, etc. Usage ezsys( system_variable ) Parameters Name Type Description Required system_variable string The name of the desired variable. Yes. Returns A string containing… - ezpreference (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 05/04/2005
Summary Provides access to a user's preference values. Usage ezpreference( preference ) Parameters Name Type Description Required preference string The name of the preference that should be extracted. Yes. Returns A stri… - ezini_hasvariable (New)
Technical manual 6.x · Changed 09:06 am · Last updated by Balazs Halasy on 04/01/2007
Summary Returns TRUE if the specified configuration directive is set. Usage ezini_hasvariable( section, variable [, ini_file [, ini_path [, dynamic ] ] ] ) Parameters Name Type Description Required section string Section… - ezini (Updated)
Technical manual 6.x · Changed 09:06 am · Last updated by Graham Brookins on 04/01/2007
Summary Provides read access to settings in the configuration files. Usage ezini( section, variable [, ini_file [, ini_path [, dynamic [, check_existence ] ] ] ] ) Parameters Name Type Description Required section string…